Glasnarget Ridge

14 November 2011
Glasnarget Ridge
Challenge
In 2007, Randy Ralston and Mel Cronin bought a dormer bungalow in Rathdrum, Co Wicklow. Refurbishment began soon after they bought the 35 year old house, which had seen better days. The main goals for the projects where to create  an environmentally friendly house, low running costs, freedom from what Randy calls the "petroleum addiction loop", and to inspire others to go green. Naturally, they also wanted a comfortable and beautiful home.The legacy issues associated with the shape and orientation of the existing building with its  large  envelope surface area to volume ratio, meant that achieving high levels of airtightness was an extremely difficult task.
 
 
Project Name: 
 
 
  Glasnarget Ridge
Project Address:
 
 
  Rathdrum, Co. Wicklow
Category:
 
 
  Renovation Residential
Entrant:
 
 
  Integrated Energy, Archie O Donnell
Company
founded in:  
 
 
  2009
Company Address:
 
 
  53a Rathgar Avenue, Dublin 6
Company
Contact 
details:
 
 
Phone: 353(0)876843171;
 
 
Architects name:
 
 
 
 
 
Planning by Corkish Maguire Partnership, Wicklow Enterprise Park, 
Technical Architect Archie O’Donnell,
Foundation system design by Viking House and Hilliard Tanner Engineer. 
 
Specialities:
 
 
  Passive House Construction Technology
Building
Type:  
 
 
 
House Private Dwelling, Outsulated cavity wall + Timber frame 
 
Size m2:
 
 
  300m2
No of Floors: 
 
 
 
2
No of Units: 
 
 
  1
Construction date: 
  Sept 2010
 
Technical Strategy 
A whole house or systems approach was taken to determine the most cost effective approach to achieving the highest possible standards of thermal comfort, healthy breathable materials and a long life components. An evidence based approach to decision making was adopted early on and the specification was developed through the rigorous use of Passive house software and analytical tools for calculating heat loss due to cold bridging and assess vapour diffusion. In parallel  toolbox talks were conducted on site with blower door, smoke cannon and thermographic camera to demonstrate to on-site trades the crucial importance of attention to detail in the workmanship needed for passive levels of performance.
 
Performance
Energy Usage: 17.9 kWh/m²
BER: A1
Air tightness: 0.97 m3/h.m²
 
U-Value for windows: 0.8
U-Value for roof: 0.14
U-Value for ground: 0.12
U-Value for walls:  0.14
 